ISO 9001:2008 Certified Company
TAM Completion Systems
Home > Oil & Gas Applications > Test, Treat or Squeeze

TAM inflatable tools are available in single and/or straddle configurations to isolate specific customer intervals in open or cased holes for selective treating, squeezing or testing as desired.

Test, Treat or Squeeze
Inflatable treat and test tools are available for a wide variety of applications: 

  • In single and straddle configurations
  • For hole sizes from 2” through 30”
  • For open hole and cased hole applications in vertical or horizontal wells
  • With expansion capabilities in excess of 2:1
  • Can be run on drill pipe, tubing or coiled tubing

 

Selective Test & Treat
 grey_spacer.gif

Open Hole Applications
Selective Test or Treat - AcidizingSelective Test or Treat - Acidizing
Selective treating required in horizontal well to remove formation damage due to drilling operations
Selective Test or Treat - SwabbingSelective Test or Treat - Swabbing
Selective testing required in horizontal well to define water source and design a remedial program
Multi Lateral IsolationMulti Lateral Isolation
One or more legs of multi lateral producing water
Selective Testing – Jet PumpSelective Testing – Jet Pump
Selective testing required in horizontal well to define water source and design a remedial program
Multi Lateral IsolationMulti Lateral Isolation
One or more legs of multi lateral producing water
Selective CompletionSelective Completion
Vertical well completed in long reservoir interval or multiple zones require zone isolation without cementing
Smart WellIntelligent Well
Intelligent Well completion requires open hole zone isolation
Selective Testing – Stress MeasurementSelective Testing – Stress Measurement
Perforations plugged, or skin damage detected on well test analysis - Acid stimulation required
 
Cased Hole Applications
Selective Water Shut Off – Screened CompletionSelective Water Shut Off – Screened Completion
Lower screen section of gravel packers oil well completion producing excess water
Straddle Test & TreatStraddle Test & Treat
Screen/gravel pack plugged: Acid stimulation required
Straddle Test & Treat – Scale Build UpStraddle Test & Treat – Scale Build Up
Perforations plugged with scale buildup requires acid stimulation
Straddle Test & Treat – Multiple PerforationsStraddle Test & Treat – Multiple Perforations
Multiple perforation completion producing excess water requires selective testing to plan remedial operations
Straddle Test & Treat – Jet PumpStraddle Test & Treat – Jet Pump
Open hole completion suspected of producing excess water from heel, below casing shoe
Temporary Plug TestingTemporary Plug Testing
Lower perforations suspected of producing water

 

Squeeze

grey_spacer.gif
Open Hole Applications
Open Hole Plug BackOpen Hole Plug Back
End of lateral (toe) producing excess water

 

Open Hole Plug Back – Lost CirculationOpen Hole Plug Back – Lost Circulation
Severe lost circulation encountered while drilling lateral
Multi Lateral P&AMulti Lateral P&A
Complete plug and abandonment of a multi- lateral well to prevent future downhole cross flow between wells
Open Hole Hydraulic FracturingOpen Hole Hydraulic Fracturing
Coal bed methane well required hydraulic proppant fracturing of multiple beds
 
Cased Hole Applications
Shoe SqueezeShoe Squeeze
Large diameter casing shoe requires squeeze cementing
Perforation SqueezePerforation Squeeze
Lower perforations producing excess water, suspected poor cement between zones, isolation required.
Plug and Abandon (P&A) Due To Corroded TubingPlug and Abandon (P&A) Due To
Corroded Tubing

Permanently P&A an existing well with corroded tubing without using a rig
Selective Water Shut Off – Screened CompletionSelective Water Shut Off – Screened Completion
Lower screen section of gravel packers oil well completion producing excess water

 

 

 
© TAM International, Inc. 2012